Chart page β configuration in the admin
The chart page draws one measurement over time β as a column chart or as a line chart. It either fetches the data from a history adapter (InfluxDB, History, SQL) itself, or it takes ready-made values out of two states of your own.
You create it in the PageConfig tab, page type Chart. No configuration script is needed for that; pages from the old table Page Chart reach this page type through the Migration.
Contents:
- Creating the page
- Chart type: columns or line
- Headline, colour, axis label
- Data source: the switch
- Way A: data from a history adapter
- Way B: data from your own states
- The y-axis and the two-character rule
- The time axis
- When the panel redraws
- Panel assignment and navigation
- Pages from the old table βPage Chart"
- Pitfalls
1. Creating the page
- Open the instance settings β tab PageConfig.
- On the left pick the page type Chart, enter a name in the field New Page, press +.
- The page appears in the list and the editor opens on the right.
A freshly created page is set to Column chart, Script version, colour yellow, Range in hours 24, X-axis ticks 2, X-axis labels 4 and Factor for card chart 1. The Headline is pre-filled with the page name.
As with every card type all fields are locked while the instance is not running β without an explanation in the editor.
2. Chart type: columns or line
Chart type is a radio group offering Column chart and Line chart. The choice decides more than just the look:
| Column chart | Line chart | |
|---|---|---|
| Resolution from the database | one average per hour | 5-minute grid, at most 500 points |
| Y-axis | minimum fixed at 0 | spans across the data |
| Handling large numbers | manual factor | automatic |
| X-axis spacing | labels only | ticks and labels set separately |
Rule of thumb: columns for hourly values (consumption per hour), line for a progression (temperature).

The two pictures show the differences: the line chart (left) spans the y-axis across the data β here 11 to 22 Β°C. The column chart (right) always starts at 0 and shows one column per hour. Both axis labels stay two digits, which is the limit of the panel (see section 7). The time labels show the spacing: every four hours on the left, at every hour divisible by four on the right.
Internally both variants carry the same card type cardChart; the chart type is a field of the page. That explains why switching between columns and line needs no new page β and why the Documentation link reads the same for both (see section 10).
3. Headline, colour, axis label
| Field | Effect |
|---|---|
| Unique ID | Page name; other pages address this page under it in their navigation targets. Read-only β the name is fixed once the page exists ("The name is fixed once the page exists - other pages refer to it."); on the start page its own note stands there: Start page - published under the id βmain". See PageConfig β Overview. |
| Headline | Header line on the panel. Left empty, the panel shows Page Chart. |
| Select color for chart | Colour of the curve or of the columns, as a colour picker. Default yellow. |
| y-axis label | Text next to the axis, for example W. The line chart appends its automatic factor here when needed β W then becomes W x10. The field is present for both data sources. |
There is one colour and one series per page. The card cannot show several curves in one chart, and accordingly there is no legend β the "legend" consists of the headline and the axis label.
4. Data source: the switch
The radio group Data source decides where the values come from:
| Choice | Meaning |
|---|---|
| Database adapter | The adapter queries a history adapter itself and works out the presentation. Only with this do the Database instance, the range, the factor and the axis spacing appear. |
| Script version | Axis and values come ready-made from two states of your own. For special cases the automatic way does not cover. |
Which fields appear below depends on this choice alone; the next two sections describe the two ways. Switching only hides the fields of the other way β their values stay stored and are back after switching again.
5. Way A: data from a history adapter

| Field | Effect |
|---|---|
| Database instance | The instance of the history adapter. The list holds the enabled instances of InfluxDB, History and SQL β the editor knows no other history adapters. With none present it says No instance found. |
| Data point for values from the database | The measurement. The picker only shows states that are actually being logged in the selected instance; without a selected instance, all those any history adapter records. That is the most useful check in the whole editor. |
| Range in hours | How far back it draws; the window always ends "now". Default 24, lowest value 1 β there is no upper limit. |
| Factor for card chart | Only for the column chart. Converts the values before they go to the panel β 0.001 turns watts into kilowatts, so the y-axis labels fit into two characters (see section 7). A tooltip on the field states the direction. |
The adapter requests the data as averages (getHistory with aggregate: average) β one value per hour for the column chart, a 5-minute grid with at most 500 points for the line chart. If the selected instance is not running, the chart stays empty and there is only a warning in the log. If it does not answer, the query aborts after 15 seconds with an error in the log.
Without an instance or without a state, the page falls back to the script way silently β and then shows an empty chart, because the script states are empty. There is no message in the admin. So if you see an empty chart, first check that both fields are filled.
Vanished instance: if the selected instance is later disabled or removed, the field shows empty β but it is still stored. The page then looks unconfigured when it is not.
The factor offers
1,0.1,0.01,0.001. The chosen factor is applied to the measurement before it goes to the panel:0.001means "divide by 1000", so watts β kilowatts. The tooltip on the field says so literally: The values from the database are multiplied by this factor before they are shown (0.1 = divided by 10).
6. Way B: data from your own states

With Script version two different fields appear. Here the adapter computes nothing β it passes on whatever is in the states. So the panel format has to be ready there already.
| Field | Effect |
|---|---|
| Data point for ticks | A JSON array with the values of the y-axis. If the content is not an array or is empty, it is ignored. |
| Data point for values | A string in panel format that is passed on unchanged: for the column chart value^label~value~β¦, for the line chart ticks+labels~position:value~β¦. |
Both states are watched (see section 9). Range, factor and axis spacing do not exist in this way β they sit in the values you deliver.
This way is meant for cases the automatic way does not fit. There is no automatic scaling here: you have to keep to the panel's two-character rule yourself.
7. The y-axis and the two-character rule
It pays to know the panel's contract here, because it explains almost every odd-looking chart:
- Values and tick marks go to the panel multiplied by 10; the panel divides by 10 again and prints every mark as a whole number of at most two characters β the range that can be shown is therefore β9 to 99. 1520 becomes "15".
- The panel spans the axis exactly across the data and shows only marks inside that range. Extra marks above or below are invisible β so there is no way to give the curve headroom like that.
For the two chart types this means:
Line chart β does it by itself. The adapter picks the step as the smallest 1-2-5 value that gives at most five steps across the span, and places marks from the step below the minimum to the step above it, at least two. If a mark does not fit into two characters, it raises the factor in steps of ten (up to a maximum of 1,000,000) until it does, and appends it to the axis label β W then becomes W x10. Nothing to do for that.
Column chart β here you have to act. It computes more simply: minimum always 0, step about one fifth of the maximum with a lower bound that grows with the maximum. There is no automatic safeguard against labels that are too long β that is what the factor is for. If the axis shows nonsense, the factor is the first lever.
In neither case is there a setting for minimum, maximum or step of the y-axis.
8. The time axis
Two fields, both only in the Database adapter way:
| Field | Effect |
|---|---|
| X-axis ticks | Line chart only. Spacing of the ticks in hours. Default 2. Tooltip: Interval in hours between X-axis ticks (e.g., 2 for a tick every 2 hours). |
| X-axis labels | Both chart types. Spacing of the time labels in hours. Default 4. Tooltip: Interval in hours between X-axis labels (e.g., 4 for a label every 4 hours). |
For the column chart the label spacing works differently than the name suggests: labelled are the columns whose time of day is divisible by the value β with 4 that is 0, 4, 8, 12, 16, 20 o'clock. So it is not a spacing "from now", but a grid on the clock.
For the line chart the labels sit on the ticks: only a tick whose distance from the start is divisible by the label spacing gets a label. If the label spacing is not a multiple of the tick spacing β ticks 4, labels 6, for instance β labels drop out; what remains is labelled only at the least common multiple, here every 12 hours.
Both fields are set to 1 to 8: the arrows on the field do not go beyond that. A value typed by hand outside the range is still taken over, without a message β the chart then shows whatever comes out of it.
0, negative values and text clear the field, which then shows the default as a pale placeholder β and the default applies as well. Range in hours only has the lower bound 1, none at the top.
Range and resolution are linked, without the editor pointing it out: the line chart fetches at most 500 points, so the 5-minute grid gets coarser from 42 hours on. The column chart produces one column per hour β for a range of a week that is 168 columns on a narrow display.
9. When the panel redraws
The page does not draw on a fixed beat but on an occasion:
- When the page is opened. As soon as the page becomes visible on the panel, the adapter fetches the data again. So the time window always ends at the moment of opening.
- On a value change. In the Database adapter way the selected Data point for values from the database is the trigger itself; in the Script version way it is the two states for ticks and values.
- At most once per minute. Further triggers within the minute are collected and caught up in one pass afterwards.
- Only while the page is visible. As long as another page or the screensaver is on the panel, triggers are discarded.
If a database query is still running, the adapter delivers the data read last; if the instance does not answer for 15 seconds, an error appears in the log.
10. Panel assignment and navigation
Panel, navigation targets, Start page, Hidden and Screensaver behavior live in the right-hand column, described under PageConfig β Overview. A page without a panel assignment is not built at all.
The Documentation link at the bottom left of the tab builds its address from the card type, not from the chart type: column and line chart are both
cardChart, so the link leads to this page in both cases. With the page type filter on All or Main pages the link takes the card type of the selected page; with no page selected it leads to PageConfig.
11. Pages from the old table βPage Chart"
Pages taken over from the old table Page Chart show a yellow warning box at the top of the editor:
Migrated from the old table βPage Chart": this page still gets its navigation from the script (page ββ¦"). This is deprecated - assign a navigation here and remove the page from the script.
What that means: the content of this page sits entirely in this editor, but its place in the navigation still comes from a page of the configuration script. The name in the box is the script name β it differs from the name of the entry when the migration appended a suffix because of a name collision.
While that state lasts:
| Circumstance | Effect |
|---|---|
| The adapter warns at every start | the navigation from the script is deprecated β assign it in the admin (tab PageConfig, page β¦) and remove the page from the script |
| The script page only supplies navigation | Page items of the script page are always discarded; a headline set there, however, wins over the Headline of this editor. |
| Show page permanently / Hide page in the script | take effect in addition to the settings of this editor β what is set is set, and it can only be unset in the script. |
| The box disappears | as soon as the page has a panel assignment here. The script page is then a dead reference: the adapter skips it and writes gets its navigation in the admin (tab PageConfig) β remove it from the script. Skipped! into the log. |
| There is no admin entry for the script name | The page is not built at all: No chart page β¦ found in the admin configuration. |
How the migration runs, which suffixes appear and how the button Take script into the admin does the last step is described on Migration.
Pitfalls
β οΈ Empty chart despite a selected database. With the Database instance or the Data point for values from the database missing, the page silently works as Script version β with empty states and therefore an empty chart. There is no message in the admin.
The list of database instances shows enabled instances, not running ones. The editor reads the instance objects and filters on "enabled"; whether the instance runs is only checked by the adapter. An enabled but stalled instance appears in the list and yields nothing but a log warning and an empty chart at runtime.
The state field can be filled by hand. The filter "logged states only" applies only in the picker behind β¦; a typed ID is taken over unchecked. The empty chart is then the only feedback.
The factor acts as a divisor.
0.001means "divide by 1000" β the tooltip on the field says the same. It only exists for the column chart in the database way, and there it is the only protection against axis labels that are too long.
There is no headroom above or below the curve. The panel spans the y-axis exactly across the data and shows only marks inside that range. Setting more marks does not help β that applies to the script version too.
A large range does not make the chart more precise. With the line chart the 5-minute grid gets coarser from 42 hours on (the 500-point limit); with the column chart only the number of columns grows β a week gives 168.
The right-hand label of the line is not at "now". The adapter always places an additional labelled tick at the right edge 50 minutes before the current time, regardless of the configured spacing.
One series, one colour. The card knows no several curves, no two y-axes and no legend.
All fields stay locked while the instance is not running. The editor does not say why.
After the move out of the old table the work is not done. As long as the navigation comes from the script, the adapter warns at every start; only a panel assignment here plus removing the page from the script ends that. The way there is described on Migration.